Skip to main content

Table 3 Operative data for the studied sample

From: Minimally invasive aortic valve replacement with central cannulation: A cost-benefit analysis in a developing country

  

Mini-sternotomy (MS) (n = 50)

Full sternotomy (FS) (n = 52)

p

Length of skin incision (cm)

(Mean ± SD)

5.82 ± 0.67

27.64 ± 2.71

0.001

Implant type

Mechanical

38

(76)

28

(53.8)

0.16

Biological

12

(24)

24

(46.2)

Implant size (mm)

19

4

(8)

9

(17.3)

0.31

21

20

(40)

23

(44.2)

23

16

(32)

16

(30.8)

25

8

(16)

3

(5.8)

27

2

(4)

1

(0.2)

Cumulative bypass time (min)

(Mean ± SD)

91.87 ± 34.41

94.91 ± 33.96

0.66

Min, max

43, 180

50, 215

Cumulative cross-clamp time (min)

Mean ± SD

68.88 ± 29.63

65.78 ± 24.36

0.58

Min, max

70.2, 35

30, 165

Minimum core temperature (°C)

Mean ± SD

31.02 ± 2.39

30.47 ± 1.17

0.14

Min, max

31, 27

27, 32

Inotropic support

High

0

(0)

3

(5.7)

0.445

Moderate

1

(2)

2

(3.8)

Minimal

24

(48)

26

(50)

None

25

(50)

21

(38.7)

  1. Cm centimeters, mm millimeters, SD standard deviation, °C degree celcius